Peclet Number Calculator
Compare advective transport with diffusion for heat or mass transfer, in metric or imperial units.
What it does
When a fluid flows past a surface, heat and dissolved material move in two ways at once. The flow carries them along, which is advection, and random molecular motion spreads them out, which is diffusion. The Peclet number compares the speeds of those two processes in a single dimensionless value.
The definition is Pe = U L over alpha, where U is a characteristic flow speed, L is a characteristic length such as pipe diameter or plate length, and alpha is the relevant diffusivity. For heat transfer alpha is the thermal diffusivity, k over rho times cp. For mass transfer it is the diffusion coefficient D.
The same number can be written as a ratio of times. Advection needs about L over U seconds to carry something across the length scale. Diffusion needs about L squared over alpha seconds to spread the same distance. Dividing the diffusion time by the advection time gives U L over alpha, the Peclet number.
A large Peclet number says the fluid is doing most of the transporting. Temperature or concentration changes are carried downstream in thin layers, and diffusion has little time to act. A small Peclet number says diffusion wins, so the profile smooths out quickly compared with the flow. At Pe near 1 both effects matter.
The number appears in heat exchangers, pollutant transport, microfluidics and chemical reactors. NASA engineers use it alongside Reynolds, Grashof and Prandtl numbers when describing transport in gas reactors, and chemistry texts use it when discussing diffusion with drift. This page evaluates the definition directly and reports the two transport times as a sanity check.
How to use
- Pick metric or imperial units.
- Enter a characteristic flow speed.
- Enter the characteristic length for your geometry, such as a pipe diameter or plate length.
- Enter the diffusivity. Use thermal diffusivity for a heat problem or a diffusion coefficient for a mass problem.
- Read the Peclet number and the transport regime it implies.
- Check the two times. Their ratio should equal the reported Peclet number.
Formula
- Pe
- Peclet number, dimensionless.
- U
- Characteristic flow speed, in m/s or ft/s.
- L
- Characteristic length, in m or ft.
- alpha
- Thermal diffusivity or mass diffusion coefficient, in m2/s or ft2/s.
The thermal diffusivity alpha equals thermal conductivity divided by density times specific heat at constant pressure, so alpha = k / (rho cp). In mass transfer the diffusion coefficient D replaces alpha. The Peclet number is related to other similarity numbers: the thermal form is Reynolds number times Prandtl number, and the mass form is Reynolds number times Schmidt number. Because every quantity converts between unit systems, the dimensionless answer is identical in metric and imperial modes.
Worked example
Example: air flow at 0.5 m/s past a 0.1 m surface
Defaults: metric units, U = 0.5 m/s, L = 0.1 m, alpha = 0.00002 m2/s, a value typical of thermal diffusion in air near room conditions.
- The definition is Pe = U L / alpha.
- Multiply the speed by the length: 0.5 x 0.1 = 0.05 m2/s.
- Divide by the diffusivity: 0.05 / 0.00002 = 2500.
- Advection time = L / U = 0.1 / 0.5 = 0.200 s.
- Diffusion time = L squared / alpha = 0.01 / 0.00002 = 500.0 s.
- The ratio of those times is 500.0 / 0.200 = 2500, which matches the direct calculation.
- Pe is well above 1, so advection dominates. The tool shows 2,500.00, Advection dominated, 0.200 s and 500.0 s.
Reference table
| Medium | Diffusivity (m2/s) | Peclet number | Dominant process |
|---|---|---|---|
| Air, heat | 0.00002 | 2,500.00 | Advection |
| Water, heat | 0.00000014 | 357,142.86 | Advection |
| Air, mass | 0.00001 | 5,000.00 | Advection |
| Slow diffusion in gel | 0.001 | 50.00 | Advection |
Limits
- The result is only as good as the chosen length scale, which must match the geometry of the problem.
- A single diffusivity assumes constant material properties. In practice viscosity and diffusivity can vary with temperature.
- The definition says nothing about whether the flow is laminar or turbulent. Reynolds number must be checked separately.
- At very small Peclet numbers diffusion smooths gradients so quickly that the flow detail may be unimportant.
Common mistakes
- Using thermal conductivity in place of thermal diffusivity, which leaves the wrong units in the ratio.
- Mixing a length in millimetres with a speed in metres per second.
- Confusing the thermal and mass forms, which need different diffusivities.
- Entering a kinematic viscosity when a mass diffusion coefficient is required.
- Assuming a large Peclet number means fast flow in absolute terms. It only compares two transport rates.
Try it yourself
Quick checks. Answers sit tucked under each question.
U = 0.2 m/s, L = 0.05 m, alpha = 0.00002 m2/s. Find Pe and the two times.
Pe = 0.2 x 0.05 / 0.00002 = 500.00. Advection time is 0.250 s and diffusion time is 125.0 s, whose ratio is again 500.
U = 1 m/s, L = 1 m and alpha = 0.01 m2/s. What regime is this?
Pe = 1 x 1 / 0.01 = 100.00, so advection dominated. Advection takes 1.000 s and diffusion takes 100.0 s.
The imperial example uses 1.64042 ft/s, 0.328084 ft and 0.000215278 ft2/s. What appears?
Those are the metric defaults converted exactly, so Pe is still 2,500.00 with a 0.200 s advection time and a 500.0 s diffusion time.
Questions
What does a Peclet number of 1 mean?
Advection and diffusion happen on the same time scale over the chosen length. Neither process can be ignored.
How is Pe related to Reynolds and Prandtl numbers?
The thermal Peclet number equals Reynolds number times Prandtl number. The mass transfer form equals Reynolds number times Schmidt number.
Is the Peclet number a property of the fluid?
No. Unlike Prandtl number, it also depends on the flow speed and the length scale of the geometry.
Which diffusivity should I enter?
Use thermal diffusivity for heat transport and a mass diffusion coefficient for concentration transport. The two give different Peclet numbers for the same flow.
Why do metric and imperial give the same answer?
Every term converts consistently, so the units cancel. The tool converts imperial inputs to SI before taking the ratio.
Does a high Pe mean heat transfer is efficient?
It means heat is carried by the flow rather than spread by conduction. Whether that helps depends on the design goal and the heat transfer coefficient.
Sources
- NASA Technical Reports Server: Dimensionless Numbers Expressed in Terms of Common CVD Process Parameters
- Chemistry LibreTexts: Diffusion with Drift, section on the Peclet Number