Nusselt Number Calculator

Compare convective heat transfer with pure conduction across a fluid layer, in metric or imperial units.

Physics and EnergyUpdated 2026-11-183 min read
Nusselt Number Calculator
Pipe diameter for internal flow, plate length for a flat plate, or plate height for natural convection.
Nusselt number
...
Convection versus conduction...
Conduction only coefficient...
Dominant mechanism...

What it does

A hot surface in still air loses heat by conduction through the thin fluid layer next to it. Start a fan and the same surface loses heat much faster, because moving fluid repeatedly replaces the warmed layer with cool fluid. The Nusselt number measures that enhancement in a single dimensionless value.

The definition is Nu = h L over k. Here h is the convective heat transfer coefficient from Newton's law of cooling, L is a characteristic length chosen for the geometry, and k is the thermal conductivity of the fluid, not the solid. A Nusselt number of 1 corresponds to a stagnant fluid layer with pure conduction. Values well above 1 mean convection is doing most of the work.

Rose Hulman course notes describe the number as a dimensionless heat transfer coefficient and stress that choosing the right characteristic length is essential. For flow inside a round pipe it is the pipe diameter, for a flat plate it is the plate length, and for a vertical plate in natural convection it is the plate height. Perry's Chemical Engineers Handbook lists the same hD over k or hL over k definition.

Nusselt numbers are usually obtained from empirical correlations that depend on Reynolds and Prandtl numbers for forced convection, or Grashof and Prandtl numbers for natural convection. NASA engineers compare several such correlations when designing cooling channels for nuclear thermal rockets, because the choice of correlation can shift predicted wall temperatures substantially even when pressure drop barely changes.

This page evaluates the definition itself. Give it a heat transfer coefficient, a length and a fluid conductivity, and it returns the Nusselt number, the conduction only coefficient k over L, and a plain language read on which mechanism dominates.

How to use

  1. Pick metric or imperial units.
  2. Enter the convective heat transfer coefficient for your surface.
  3. Enter the characteristic length for your geometry.
  4. Enter the thermal conductivity of the fluid, not the wall material.
  5. Read the Nusselt number and compare it with 1.
  6. Use the conduction only coefficient to see what the same layer would do with no fluid motion.

Formula

Nu = h L / k, with h in W/(m2 K), L in m and k in W/(m K). The conduction only coefficient is k / L in W/(m2 K). In imperial units use h in BTU/(h ft2 °F), L in ft and k in BTU/(h ft °F).
Nu
Nusselt number, dimensionless.
h
Convective heat transfer coefficient, in W/(m2 K) or BTU/(h ft2 °F).
L
Characteristic length of the geometry, in m or ft.
k
Thermal conductivity of the fluid, in W/(m K) or BTU/(h ft °F).

The heat transfer coefficient h is not a material property. It depends on flow speed, geometry and fluid properties, which is why correlations are used to predict it. The Nusselt number packages h into a form that can be correlated with Reynolds and Prandtl numbers. For internal turbulent flow a common starting point is the Dittus Boelter correlation, while many other geometries have their own fitted relations. This tool does not choose a correlation for you; it converts a known h into Nu.

Worked example

Example: a 0.5 m surface with h = 50 and k = 0.6

Defaults: metric units, h = 50 W/(m2 K), L = 0.5 m and fluid conductivity k = 0.6 W/(m K).

  1. The definition is Nu = h L / k.
  2. Multiply the coefficient by the length: 50 x 0.5 = 25 W/(m K).
  3. Divide by the fluid conductivity: 25 / 0.6 = 41.6667, which rounds to 41.67.
  4. With no fluid motion the coefficient would be k / L = 0.6 / 0.5 = 1.20 W/(m2 K).
  5. The ratio of the two coefficients is 50 / 1.2 = 41.7, the same as Nu.
  6. Convection therefore moves heat about 41.7 times faster than conduction alone across this layer.
  7. The tool shows 41.67, 41.7 times conduction, 1.20 W/(m2 K) and Convection dominates.

Reference table

Characteristic length for common geometries
GeometryCharacteristic length LTypical useNu for pure conduction
Internal flow in a round pipePipe diameter DForced convection in tubes1
Flow along a flat platePlate length from the leading edgeExternal forced convection1
Flow past a cylinderCylinder diameterCross flow heat transfer1
Vertical plate in still fluidPlate heightNatural convection1

Limits

  • The result is only as reliable as the input heat transfer coefficient.
  • A single characteristic length cannot represent a complex shape with several length scales.
  • The definition assumes a clear temperature difference between surface and bulk fluid.
  • Radiation heat transfer is not included and must be added separately when it matters.

Common mistakes

  • Entering the thermal conductivity of the wall instead of the fluid.
  • Using the plate thickness rather than the correct characteristic length for the geometry.
  • Mixing a coefficient in W per square metre kelvin with a conductivity in BTU units.
  • Assuming Nu is a fluid property like Prandtl number. It also depends on flow and geometry.
  • Forgetting that Nu equal to 1 is the conduction baseline, so values below 1 are physically unusual.

Try it yourself

Quick checks. Answers sit tucked under each question.

h = 100 W/(m2 K), L = 0.2 m and k = 0.6 W/(m K). What is Nu?

Nu = 100 x 0.2 / 0.6 = 33.33. The conduction only coefficient is 0.6 / 0.2 = 3.00 W/(m2 K).

h = 20, L = 1 m and fluid k = 0.04. Find Nu.

Nu = 20 x 1 / 0.04 = 500.00. Convection is about 500 times conduction, and the conduction only coefficient is 0.04 W/(m2 K).

The imperial defaults use 8.80551 BTU/(h ft2 °F), 1.64042 ft and 0.346674 BTU/(h ft °F). What appears?

These are the metric defaults converted exactly, so Nu is still 41.67 and convection still dominates. The conduction only coefficient reads 0.21 BTU/(h ft2 °F).

Questions

What does a Nusselt number of 1 mean?

Heat is moving by pure conduction through a stagnant fluid layer of thickness L. Any fluid motion pushes the value above 1.

Is Nusselt number a fluid property?

No. It depends on the heat transfer coefficient, which reflects flow and geometry, as well as the fluid conductivity.

How do I find h?

Usually from an empirical correlation using Reynolds and Prandtl numbers for forced convection, or from experiment. This page starts once h is known.

Which length should I use for a pipe?

For internal flow in a circular pipe the characteristic length is the pipe diameter. Non circular ducts use hydraulic diameter.

Does imperial input change the answer?

No. Imperial values are converted to SI before the ratio is taken, so the dimensionless result matches the metric mode.

Does this include radiation?

No. Radiation follows different physics and is normally added as a separate parallel heat transfer path.

Sources

How this page was checked. The formula above was matched against the cited sources, and the worked example was run through the tool on this page before publishing. If you spot an error, contact us so we can fix it and note the correction.