Prandtl Number Calculator
Compare momentum diffusivity with thermal diffusivity for common fluids, in metric or imperial units.
What it does
Heat and momentum both spread through a moving fluid, but they do not spread at the same rate. The Prandtl number compares the two rates. It is named after Ludwig Prandtl and is one of the standard similarity numbers used to correlate heat transfer in pipes, boundary layers and free convection.
The definition is Pr = nu over alpha, where nu is kinematic viscosity and alpha is thermal diffusivity. Substituting nu = mu over rho and alpha = k over rho cp cancels the density and leaves the more convenient form Pr = cp mu over k. That is the form this page evaluates, using specific heat at constant pressure.
The Encyclopedia of Mathematics gives both forms and notes the connection Pr = Pe over Re, linking it to the Peclet and Reynolds numbers. A NASA Lewis Research Center paper expresses the same number in terms of gas properties and reports values near 0.667 for monatomic gases and 0.690 for diatomic gases under its assumptions.
The size of Pr tells you which boundary layer is thicker. When Pr is much larger than 1, momentum diffuses faster than heat and the thermal boundary layer is thinner than the velocity boundary layer. When Pr is much smaller than 1, as in liquid metals, heat diffuses rapidly and the thermal layer is much thicker.
The tool ships with representative properties for water, air, mercury and engine oil, all converted internally to SI so that the dimensionless answer is identical in metric and imperial modes. You can also enter your own fluid properties if you have a reliable table for the temperature of interest.
How to use
- Pick metric or imperial units for any custom values you plan to enter.
- Choose a fluid from the list, or choose your own values.
- If using your own values, enter specific heat, dynamic viscosity and thermal conductivity in the units shown.
- Read the Prandtl number and the short description of the heat diffusion regime.
- Compare with a published value for the fluid at your temperature as a check.
- Remember that the result is dimensionless, so it does not depend on the unit system.
Formula
- Pr
- Prandtl number, dimensionless.
- cp
- Specific heat at constant pressure, in J/(kg K) or BTU/(lb °F).
- mu
- Dynamic viscosity, in Pa s or lb/(ft h).
- k
- Thermal conductivity, in W/(m K) or BTU/(h ft °F).
- nu
- Kinematic viscosity, equal to mu divided by density.
- alpha
- Thermal diffusivity, equal to k divided by density times cp.
The preset values are representative room temperature data. Water uses cp 4182 J per kg K, viscosity 0.001002 Pa s and conductivity 0.598 W per m K, giving a Prandtl number near 7. Air gives about 0.71, mercury about 0.025 and a typical engine oil several thousand. Because properties vary with temperature, a value from a handbook at your actual temperature is always better than a generic table value.
Worked example
Example: water at 20 °C
Defaults: metric units with the water preset, cp = 4182 J/(kg K), mu = 0.001002 Pa s and k = 0.598 W/(m K).
- The convenient form is Pr = cp x mu / k.
- Multiply specific heat by viscosity: 4182 x 0.001002 = 4.190364.
- Divide by thermal conductivity: 4.190364 / 0.598 = 7.009.
- Rounded to two decimals the Prandtl number is 7.01.
- Momentum therefore diffuses about 7.0 times faster than heat in water at this temperature.
- Imperial inputs are converted to SI first, so they give the same 7.01.
- The tool shows 7.01, 7.0 times more momentum diffusion and High Pr: heat diffuses slowly.
Reference table
| Fluid | cp (J/kg K) | Viscosity (Pa s) | k (W/m K) | Pr |
|---|---|---|---|---|
| Water at 20 °C | 4182 | 0.001002 | 0.598 | 7.01 |
| Air at 20 °C | 1005 | 0.0000181 | 0.0257 | 0.71 |
| Mercury | 139 | 0.00155 | 8.54 | 0.03 |
| Engine oil | 1900 | 0.29 | 0.15 | 3,673.33 |
Limits
- Properties change with temperature and pressure, so a single number is only valid near the stated conditions.
- The formula assumes a Newtonian fluid with constant properties.
- It says nothing about flow regime, which must be judged with the Reynolds number.
- Mixtures and non Newtonian fluids need measured properties and a more careful model.
Common mistakes
- Using kinematic viscosity in a formula that calls for dynamic viscosity, or the other way around.
- Mixing units from different systems when entering a custom fluid.
- Forgetting to use specific heat at constant pressure rather than constant volume.
- Assuming a Prandtl number depends on flow speed. It is a property of the fluid state.
- Reading a very small Prandtl number to two decimals and losing the useful detail.
Try it yourself
Quick checks. Answers sit tucked under each question.
What is the Prandtl number of air at 20 °C with the preset values?
1005 x 0.0000181 / 0.0257 = 0.71. This is below 1, so heat diffuses faster than momentum and the tool reports Low Pr: heat diffuses quickly.
Engine oil has cp 1900, viscosity 0.29 Pa s and k 0.15 W per m K. Find Pr.
1900 x 0.29 / 0.15 = 3,673.33. The thermal boundary layer is very thin compared with the velocity boundary layer.
Does the imperial mode change the water answer?
No. Imperial property values are converted to SI inside the engine, so water still gives 7.01 in both systems.
Questions
What does a Prandtl number above 1 mean?
Momentum diffusivity is larger than thermal diffusivity. The velocity boundary layer grows faster than the thermal one, as in water and oils.
Why is the Prandtl number of liquid metals so small?
Metals conduct heat extremely well, so thermal diffusivity is large while viscosity is modest. That makes the ratio small.
Does Prandtl number have units?
No. All units cancel, which is why it is called a similarity number and why metric and imperial inputs give the same answer.
How is it related to Peclet number?
The thermal Peclet number equals Reynolds number times Prandtl number, or equivalently Pr equals Pe over Re.
Can I enter my own fluid?
Yes. Choose your own values and enter cp, viscosity and conductivity in the units shown for the selected system.
Which temperature should I use for the properties?
Use the film temperature or the bulk temperature of your application and take the values from a reliable property table at that temperature.
Sources
- Encyclopedia of Mathematics: Prandtl number definition and relations
- NASA Technical Reports Server: Dimensionless Numbers Expressed in Terms of Common CVD Process Parameters