Return Loss Calculator
Convert a reflection coefficient magnitude into return loss and reflected power.
What it does
Return loss measures how much of a forward wave is reflected by an impedance mismatch. It is the ratio of incident power to reflected power expressed in decibels, and it is one of the most common specifications for antennas, cables and RF components.
The calculation uses the magnitude of the voltage reflection coefficient. Return loss is minus twenty times the base ten logarithm of that magnitude. The phase of the reflection coefficient is discarded, so return loss cannot tell you the load impedance on its own.
A perfect match has zero reflection and infinite return loss. A total reflection, such as an open or short circuit, has a reflection magnitude of one and a return loss of zero decibels. Good practical matches often aim for return loss above ten or fifteen decibels.
Reflected power is the square of the reflection coefficient. With a magnitude of 0.2, four percent of the forward power is reflected and ninety six percent is delivered. That relationship makes it easy to see why small reflection coefficients are desirable.
The result assumes a passive load and a reference impedance, often fifty ohms. Return loss is frequency dependent and can be measured as minus twenty log of the magnitude of S11 for a one port device.
How to use
- Enter the magnitude of the reflection coefficient.
- Read the return loss in decibels.
- Read the reflected and delivered power percentages.
- Use a smaller reflection magnitude to see a better match.
- Check that the reference impedance matches your measurement system.
- Remember that return loss does not give the phase of the reflection.
Formula
- |Γ|
- Magnitude of the voltage reflection coefficient.
- Return loss
- Incident to reflected power ratio in decibels.
- Reflected power
- Fraction of forward power returned toward the source.
The equivalent power form is ten times the log of incident power over reflected power. A reflection magnitude of one is rejected because the return loss would be zero and the logarithm still defined, but the tool keeps inputs below one to describe passive non total reflections.
Worked example
Example: reflection coefficient 0.2
Default input: reflection coefficient magnitude 0.2.
- Take the base ten log of 0.2, about -0.6990.
- Multiply by minus twenty: 13.98 dB.
- Square the magnitude: 0.2² = 0.04.
- Reflected power is 4.00 percent.
- Delivered power is 100 minus 4, or 96.00 percent.
- The tool shows 13.98 dB, 4.00 % and 96.00 %.
Reference table
| |Γ| | Return loss | Reflected power |
|---|---|---|
| 0.01 | 40.00 dB | 0.01 % |
| 0.1 | 20.00 dB | 1.00 % |
| 0.2 | 13.98 dB | 4.00 % |
| 0.5 | 6.02 dB | 25.00 % |
Limits
- Ignores the phase of the reflection coefficient.
- Assumes a passive load with magnitude below one.
- Return loss depends on the reference impedance and frequency.
- Does not include insertion loss or transmission effects.
Common mistakes
- Using the reflection coefficient directly as a decibel value.
- Confusing return loss with voltage standing wave ratio.
- Forgetting that reflected power is the square of the magnitude.
- Expecting return loss to reveal the complex load impedance.
- Comparing values measured against different reference impedances.
Try it yourself
Quick checks. Answers sit tucked under each question.
What is the return loss for a reflection magnitude of 0.1?
Minus twenty times the log of 0.1 is 20.00 dB, with 1.00 percent reflected power.
What does a perfect match report?
The tool reports Perfect match for return loss, with 0.00 percent reflected and 100.00 percent delivered power.
Why is reflected power the square of the coefficient?
The reflection coefficient is an amplitude ratio, while power is proportional to amplitude squared.
Questions
What is return loss?
A decibel measure of how much incident power is reflected by a mismatch.
Is higher return loss better?
Yes. A larger value means less reflected power and a better match.
How is it related to S11?
For a one port device, return loss is minus twenty log of the magnitude of S11.
What is a typical target?
Many systems aim for better than 10 dB, with 15 dB or more for demanding links.
Does return loss give the impedance?
No. It discards phase, so more information is needed to recover the complex impedance.
Why use decibels?
Because reflection ratios span many orders of magnitude and link budgets are additive in decibels.
Sources
- University of Kansas, Microwave Engineering: Power Flow and Return Loss
- University of California Santa Barbara, Impedance Matching notes
- Engineering LibreTexts, Microwave and RF Design III: Return Loss