VSWR Calculator

Convert a reflection coefficient into standing wave ratio and reflected power.

Technology and NetUpdated 2026-11-203 min read
VSWR Calculator
A number from 0 for a perfect match up to just under 1 for total reflection.
Voltage standing wave ratio
...
Reflected power...
Delivered power...

What it does

When a transmission line is not perfectly matched to its load, part of the forward wave is reflected. The forward and reflected waves add to form a standing wave with repeating maxima and minima of voltage. The voltage standing wave ratio, or VSWR, is the ratio of those maximum and minimum voltages.

VSWR is usually computed from the reflection coefficient magnitude, written as the absolute value of gamma. The formula is one plus gamma divided by one minus gamma. A perfect match has gamma zero and a VSWR of exactly one. Complete reflection has gamma one and an infinite VSWR, because the minimum voltage goes to zero.

The reflected fraction of power is gamma squared. With gamma equal to 0.2, four percent of the forward power is reflected and ninety six percent is delivered to the load. That power shuttles back toward the source, where it can cause heating or require a matching network to be absorbed.

A low VSWR is desirable in most radio and microwave systems, but the target depends on the application. A value of 1.5:1 is often acceptable, while precision systems may need much better. The tool shows the ratio and the reflected power so you can judge the trade off.

The simple relationship assumes a passive load and an ideal lossless line. On a lossy line the reflection magnitude changes with position, so the measured VSWR depends on where along the line the measurement is taken.

How to use

  1. Measure or obtain the magnitude of the reflection coefficient.
  2. Enter a value from zero up to just under one.
  3. Read the VSWR in ratio form.
  4. Read the percentage of power reflected and delivered.
  5. Try smaller reflection values to see how quickly reflected power falls.
  6. Remember that VSWR alone does not reveal the phase of the reflection.

Formula

VSWR = (1 + |Γ|) / (1 - |Γ|). Reflected power fraction = |Γ|².
|Γ|
Magnitude of the voltage reflection coefficient.
VSWR
Ratio of maximum to minimum standing wave voltage.
|Γ|²
Fraction of forward power reflected by the load.

For a load ZL on a line with real characteristic impedance Z0, the reflection coefficient is ZL minus Z0 divided by ZL plus Z0. This page takes its magnitude directly. A magnitude of one is rejected because VSWR would be infinite and the displayed number would be meaningless.

Worked example

Example: reflection coefficient 0.2

Default input: reflection coefficient magnitude 0.2.

  1. Add one to the magnitude: 1 + 0.2 = 1.2.
  2. Subtract from one: 1 - 0.2 = 0.8.
  3. Divide: 1.2 / 0.8 = 1.500.
  4. Square the magnitude: 0.2² = 0.04, so 4.00 % is reflected.
  5. Subtract from 100 %: 96.00 % is delivered.
  6. The tool shows 1.500:1, 4.00 % and 96.00 %.

Reference table

Reflection coefficient, VSWR and reflected power
|Γ|VSWRReflected power
01.000:10.00 %
0.11.222:11.00 %
0.21.500:14.00 %
0.53.000:125.00 %
0.919.000:181.00 %

Limits

  • Assumes a passive load with reflection magnitude below one.
  • Uses an ideal lossless line for the standing wave relationship.
  • Does not give the phase of the reflection coefficient.
  • Does not account for source mismatch or multiple reflections.

Common mistakes

  • Entering a reflection magnitude of exactly one.
  • Confusing VSWR with the reflection coefficient itself.
  • Using gamma instead of gamma squared for reflected power.
  • Assuming a good VSWR guarantees efficient radiation from an antenna.
  • Ignoring losses in the line when interpreting a measured value.

Try it yourself

Quick checks. Answers sit tucked under each question.

A perfect match has reflection coefficient zero. What does the tool show?

VSWR 1.000:1, reflected power 0.00 % and delivered power 100.00 %.

What if the magnitude is 0.5?

VSWR is 1.5 / 0.5 = 3.000:1 and reflected power is 0.25 or 25.00 %.

Why is reflected power the square of the magnitude?

Voltage reflection coefficient applies to wave amplitude, while power is proportional to amplitude squared.

Questions

What is VSWR?

It is the ratio of the maximum to minimum voltage in the standing wave formed by forward and reflected waves on a line.

What is a good VSWR?

Values near 1:1 are best. Many systems accept up to about 1.5:1, though requirements vary.

How is VSWR related to reflection coefficient?

VSWR equals one plus the magnitude of gamma divided by one minus it.

Why does reflection waste power?

Reflected power travels back toward the source instead of being delivered to the load, where it may be dissipated or cause instability.

Can VSWR be infinite?

In theory yes, for total reflection with gamma equal to one. The tool rejects that input because the ratio is not finite.

Does VSWR tell me the load impedance?

No. It gives only the magnitude of reflection. The phase is needed to recover the complex load impedance.

Sources

How this page was checked. The formula above was matched against the cited sources, and the worked example was run through the tool on this page before publishing. If you spot an error, contact us so we can fix it and note the correction.