Zeeman Splitting Calculator

Find the energy shift of a magnetic sublevel from g factor, field and magnetic quantum number.

Physics and EnergyUpdated 2026-11-202 min read
Zeeman Splitting Calculator
Energy shift
...
Shift in electronvolts...
Equivalent frequency...

What it does

The Zeeman effect describes how atomic energy levels split in an external magnetic field. A level with total angular momentum J separates into sublevels labelled by the magnetic quantum number m. In a weak field the shift of each sublevel is proportional to the field strength and to m.

The constant of proportionality is the product of the Landé g factor and the Bohr magneton. The Bohr magneton is the natural magnetic moment scale for an electron and equals elementary charge times reduced Planck constant divided by twice the electron mass.

This tool computes the shift for one sublevel given g, field and m. It prints the energy in joules and electronvolts and the equivalent frequency from Planck relation. A g factor near 2 is typical for a spin only electron, while other levels have different values from the Landé formula.

For a field of one tesla and g equal to two, the adjacent sublevel spacing is about 1.855 times ten to the minus twenty three joules, or roughly 28 gigahertz. That places the splitting in the microwave range.

The result assumes a weak field where J remains a good quantum number and only the linear term matters. Strong fields produce the Paschen Back effect, and observed optical transition splittings also depend on the g factors of both the upper and lower levels.

How to use

  1. Enter the Landé g factor for the level.
  2. Enter the magnetic flux density in tesla.
  3. Enter the magnetic quantum number m.
  4. Read the energy shift in joules and electronvolts.
  5. Read the equivalent frequency in gigahertz.
  6. Compare adjacent m values to find the level spacing.

Formula

Delta E = g x mu_B x B x m, with mu_B = e hbar / (2 m_e).
g
Landé g factor for the level.
mu_B
Bohr magneton, 9.2740100783e-24 J/T.
B
Magnetic flux density in tesla.
m
Magnetic quantum number of the sublevel.

Adjacent sublevels differ by one in m, so their spacing is g mu_B B. The frequency output is the shift divided by Planck constant. A negative m gives a negative shift because the sublevel moves down in energy.

Worked example

Example: g = 2 at 1 T with m = 1

Defaults: g 2, field 1 T and m 1.

  1. Bohr magneton is 9.274e-24 J/T.
  2. Multiply by g and field: 2 x 1 x 9.274e-24 = 1.855e-23 J.
  3. Divide by electron charge to get 0.000116 eV.
  4. Divide by Planck constant to get about 2.799e10 Hz.
  5. That is 27.992 GHz.
  6. The tool shows 1.855e-23 J, 0.000116 eV and 27.992 GHz.

Reference table

Zeeman shift at 1 T with g = 2
mShiftFrequency
-1-1.855e-23 J-27.992 GHz
00 J0 GHz
11.855e-23 J27.992 GHz

Limits

  • First order weak field approximation only.
  • Does not model the Paschen Back regime.
  • Requires a known g factor for the level.
  • Optical transition splitting also depends on both levels involved.

Common mistakes

  • Using a field in gauss where tesla is expected.
  • Assuming the g factor is always two.
  • Treating the shift of one sublevel as the observed line splitting.
  • Applying the formula in a strong magnetic field.
  • Forgetting that m can be negative.

Try it yourself

Quick checks. Answers sit tucked under each question.

What is the spacing between adjacent sublevels at 1 T with g = 2?

It is g mu_B B, about 1.855e-23 J or 27.992 GHz.

What happens when m is zero?

The shift is zero because that sublevel is at the unperturbed energy.

Why is the result only approximate?

It keeps the linear term in the field. Higher order effects appear in stronger fields.

Questions

What is the Zeeman effect?

The splitting of atomic energy levels in an external magnetic field.

What is the Bohr magneton?

The natural electron magnetic moment scale, about 9.274e-24 joules per tesla.

How do I find g?

For LS coupling it comes from the Landé formula using L, S and J.

Does every sublevel shift the same amount?

No. The shift is proportional to m, so sublevels move by integer multiples of g mu_B B.

When does the formula fail?

In strong fields where the Paschen Back effect takes over.

Why is frequency useful?

Spectroscopy measures transition frequencies, and dividing the shift by Planck constant gives that scale.

Sources

How this page was checked. The formula above was matched against the cited sources, and the worked example was run through the tool on this page before publishing. If you spot an error, contact us so we can fix it and note the correction.