Strouhal Number Calculator
Relate shedding frequency, body size and flow speed for oscillating flows.
What it does
When flow passes a blunt body, vortices peel off alternately and create an oscillating force. The Strouhal number packages that shedding frequency with the body size and flow speed into one dimensionless value, letting results from small laboratory models apply to much larger structures.
It is defined as frequency times a characteristic length divided by the flow velocity. For a circular cylinder the length is the diameter, while for a blunt trailing edge it may be the edge thickness. Changing that convention changes the number, so always state which length was used.
Engineers use the value to estimate shedding frequencies for bridges, chimneys, cables and airfoils. Around a circular cylinder at ordinary Reynolds numbers it sits near 0.2, but the exact figure depends on the flow regime.
The units cancel, so metric and imperial inputs give the same answer when converted. The tool also reports the oscillation period and the number of cycles per unit length, which are useful when comparing with measured time traces.
How to use
- Pick Metric or Imperial to match your data source.
- Enter the measured or predicted shedding frequency in hertz.
- Enter a characteristic length in the unit shown.
- Enter the flow velocity in the same system.
- Read the Strouhal number and the oscillation period.
- Switch systems with converted inputs to confirm the result.
Formula
- frequency
- Oscillation or shedding frequency in hertz, cycles per second.
- characteristic length
- Body scale in m or ft, matched to the source convention.
- flow velocity
- Free stream or local velocity in m/s or ft/s.
- St
- Strouhal number, a dimensionless ratio.
The period is the reciprocal of frequency and is reported in seconds. Cycles per length is frequency divided by velocity and carries an inverse length unit, so its displayed unit changes with the chosen system. The Strouhal number itself stays unit free.
Worked example
Example: 10 Hz shedding over a 0.1 m body at 2 m/s
Metric mode with frequency 10 Hz, length 0.1 m and flow velocity 2 m/s.
- Multiply frequency by length: 10 x 0.1 = 1.
- Divide by velocity: 1 / 2 = 0.5.
- The oscillation period is 1 / 10 = 0.1 s.
- Cycles per metre: 10 / 2 = 5 /m.
- Imperial check values are 0.32808399 ft and 6.56167979 ft/s.
- Their Strouhal number is also 0.5000.
- Tool shows Strouhal 0.5000, period 0.1 s and 5 /m.
Reference table
| Frequency (Hz) | Strouhal number | Period |
|---|---|---|
| 5 | 0.2500 | 0.2 s |
| 10 | 0.5000 | 0.1 s |
| 20 | 1.0000 | 0.05 s |
Limits
- Requires a clearly defined characteristic length and velocity.
- Does not predict the frequency on its own without a correlation.
- Assumes a regular periodic shedding signal.
- The value changes with Reynolds number and body shape.
Common mistakes
- Using angular frequency instead of cycles per second.
- Mixing a radius with a diameter between sources.
- Using local velocity when the source correlation uses free stream velocity.
- Forgetting that period is one divided by frequency.
- Expecting the cycles per length figure to match across unit systems.
Try it yourself
Quick checks. Answers sit tucked under each question.
Frequency 20 Hz, length 0.1 m, velocity 2 m/s. What is St?
1.0000, with a period of 0.05 s.
What does Imperial mode show for the worked example?
Strouhal 0.5000, period 0.1 s and 1.524 /ft.
If velocity doubles at the same frequency and length, what happens to St?
It halves from 0.5000 to 0.2500.
Questions
What is vortex shedding?
The alternating release of vortices from a body in a flow, which creates an oscillating side force.
Why use cycles per second?
Frequency in hertz matches the standard definition. Angular frequency would need a factor of two PI.
Which length should I choose?
Use the same one as the correlation you are comparing with, often cylinder diameter or trailing edge thickness.
Is there a universal Strouhal value?
No. A circular cylinder near common Reynolds numbers is around 0.2, but shape and flow regime matter.
How is this used in design?
To check whether shedding frequency might match a structural natural frequency and cause resonance.
Do the two unit systems give different results?
No for the Strouhal number itself. Only the cycles per length figure carries a unit and changes.