Radiation Attenuation Calculator

Apply the exponential attenuation law to a narrow photon beam.

Physics and EnergyUpdated 2026-11-202 min read
Radiation Attenuation Calculator
Any convenient intensity unit. The result uses the same unit.
Transmitted intensity
...
Percent transmitted...
Half value layer...

What it does

When a narrow beam of monoenergetic X rays or gamma rays passes through matter, its intensity falls exponentially with the distance travelled. The rate is set by the linear attenuation coefficient, which depends on the material and the photon energy.

NIST's X ray mass attenuation coefficient resource writes the law as I over I zero equals exp of minus mu times x, where x is mass thickness. The related equation uses mass thickness as density times physical thickness, which is why tables often quote the coefficient divided by density.

The University of Florida radiation protection notes give the same expression for a collimated beam and define the reciprocal of the coefficient as the mean free path. They also note that the coefficient is the sum of contributions from the photoelectric effect, Compton scattering and pair production.

This tool applies the exponential law using a linear coefficient and a physical thickness. It returns the transmitted intensity in the same units you entered, the percentage transmitted and the half value layer of the material.

The law assumes a narrow beam with no scattered photons reaching the detector. In broad beam shielding calculations a build up factor is needed, and this tool does not include one.

How to use

  1. Enter the incident intensity in any consistent unit.
  2. Enter the linear attenuation coefficient in inverse centimetres for the material and energy.
  3. Enter the physical thickness of the shield in centimetres.
  4. Read the transmitted intensity in the main result.
  5. Check the percent transmitted to see the surviving fraction.
  6. Use the half value layer to estimate how much extra shield would halve the beam again.

Formula

I = I0 x exp(-mu x). Transmitted fraction = exp(-mu x). Half value layer = ln(2) / mu.
I0
Incident intensity before the shield.
mu
Linear attenuation coefficient in inverse length units.
x
Physical thickness of the absorbing material.
I
Intensity after the shield, in the same units as I0.

The engine uses the natural exponential directly. The half value layer follows by setting I over I0 to one half and solving for x. If you have a mass attenuation coefficient instead, multiply it by the material density first to obtain the linear coefficient.

Worked example

Example: a 5 cm shield

Incident intensity 100, coefficient 0.15 per centimetre, thickness 5 centimetres.

  1. Compute the exponent: mu x = 0.15 x 5 = 0.75.
  2. The transmitted fraction is exp(-0.75) = 0.47237.
  3. Transmitted intensity is 100 x 0.47237 = 47.2367.
  4. As a percentage, that is 47.24 percent of the original beam.
  5. The half value layer is ln(2) / 0.15 = 0.6931 / 0.15 = 4.6210 centimetres.
  6. The tool reports intensity 47.2367, transmitted 47.24 percent and half value layer 4.6210 centimetres.
  7. At 10 centimetres the intensity would be 22.3130, which is roughly half of 47.2367.

Reference table

Transmission through the worked shield
Thickness cmTransmitted intensityPercent
0100.0000100.00 %
186.070886.07 %
547.236747.24 %
1022.313022.31 %

Limits

  • The law assumes a narrow, monoenergetic beam with no scattered photons counted.
  • A single coefficient does not describe a spectrum of photon energies.
  • Build up from scattered radiation is not included.
  • The coefficient must be for the correct material and photon energy.

Common mistakes

  • Using a mass attenuation coefficient where a linear coefficient is required.
  • Entering thickness in millimetres while the coefficient is per centimetre.
  • Expecting intensity to fall linearly rather than exponentially with thickness.
  • Applying the result to a broad beam without a build up correction.
  • Thinking the half value layer removes all radiation rather than half of it.

Try it yourself

Quick checks. Answers sit tucked under each question.

What is the transmitted intensity for I0 100, mu 0.15 and x 5?

47.2367, or 47.24 percent of the incident beam.

What is the half value layer for a coefficient of 0.15 per centimetre?

4.6210 centimetres, from ln(2) divided by 0.15.

What happens if you double the thickness?

The transmitted fraction is squared, because the exponent doubles.

Questions

What is the exponential attenuation law?

I equals I0 times exp of minus mu x, describing how a narrow photon beam weakens in matter.

What is the half value layer?

The thickness needed to reduce the beam intensity by half, equal to ln 2 divided by the linear attenuation coefficient.

What is the difference between linear and mass attenuation coefficients?

The linear coefficient is per unit length. The mass coefficient is per unit mass per area and must be multiplied by density to get the linear one.

Why specify a narrow beam?

So scattered photons do not reach the detector. Broad beams need a build up factor on top of the exponential law.

What contributes to the coefficient?

The photoelectric effect, Compton scattering and pair production all add to the total attenuation.

Does the tool handle multiple materials?

No. For layers you can apply the law to each layer in turn, using the intensity leaving one as the input to the next.

Sources

How this page was checked. The formula above was matched against the cited sources, and the worked example was run through the tool on this page before publishing. If you spot an error, contact us so we can fix it and note the correction.