Occupant Load Calculator
Estimate the number of people a floor area can hold from a code area per person factor.
What it does
Occupant load is the estimated number of people expected to occupy a space at one time. Building codes use it to size exits, stairs and other life safety features. For spaces without fixed seats, it is found by dividing the floor area by a prescribed area per person.
The area per person factor depends on how the space is used. Offices, assembly spaces, storage areas and retail spaces all have different values, and the exact numbers vary by jurisdiction and code edition. This page accepts a factor in square metres per person.
If a space is two hundred square metres with a factor of one square metre per person, the unrounded load is two hundred people. Code practice rounds up to a whole person, so a quotient of 200.2 would become 201.
Mixed use spaces should be calculated separately for each use and added. Fixed seating, circulation and mezzanines all have additional rules that are not implemented here.
The result does not by itself establish a legal posted capacity. Egress width, travel distance, sprinkler provisions and other code requirements also constrain how many people a space may hold.
How to use
- Identify the applicable use of the space.
- Find the area per occupant factor from the current code.
- Convert the factor to square metres per person if necessary.
- Enter the floor area and factor.
- Read the rounded occupant load.
- Apply other egress rules separately.
Formula
- Floor area
- Applicable area of the space.
- Area per occupant
- Code factor in area per person.
- Occupant load
- Estimated number of people, rounded up.
The tool reports both the unrounded quotient and the rounded value so you can see the effect of rounding. Always use the area definition required by the applicable code, which may be gross or net.
Worked example
Example: 200 m² at 1 m² per person
Defaults: floor area 200 m² and area per occupant 1 m²/person.
- Check the factor: 1 m² per person is an example value, not a universal code figure.
- The applicable floor area is 200 m².
- Divide area by factor: 200 / 1 = 200.
- The unrounded result is 200.00.
- Round up to the nearest whole person, which is 200.
- The tool shows 200, 200.00 and 200 m².
Reference table
| Area per person | Occupant load |
|---|---|
| 0.5 m² | 400 |
| 1 m² | 200 |
| 2 m² | 100 |
Limits
- Does not apply fixed seating rules.
- Factor depends on jurisdiction and code edition.
- Does not check egress capacity.
- Mixed uses need separate calculations.
Common mistakes
- Using an imperial factor without conversion.
- Applying one factor to a mixed use space.
- Treating the result as a legal capacity.
- Rounding down instead of up.
- Using the wrong gross or net area definition.
Try it yourself
Quick checks. Answers sit tucked under each question.
What is the load at 0.5 m² per person?
It is 400 people, twice the default because the factor halved.
What does rounding up mean?
A quotient of 100.2 becomes 101, because a fraction of a person is still a person for design purposes.
What if the factor is zero?
The tool returns an error because area per occupant must be positive.
Questions
What is occupant load?
An estimate of how many people occupy a space at once, used for egress design.
Where do factors come from?
Building and fire codes list factors by occupancy type.
Why round up?
Design must accommodate whole people, so any fraction rounds to the next person.
Is this a posted capacity?
No. Other code provisions also limit capacity.
How do I handle mixed uses?
Calculate each use separately and add the loads.
Does fixed seating use this method?
No. Fixed seating uses a count of seats instead.
Sources
- Minnesota Department of Public Safety: Occupant loads
- City of Portland, Building Code Guide 22-10: Office Spaces