Magnetic Flux Calculator

Find magnetic flux through a coil from field, area, angle and turns, in webers or maxwells.

Physics and EnergyUpdated 2026-11-173 min read
Magnetic Flux Calculator
Field strength in teslas.
Whole turns in the coil.
Flux per turn
...
Flux in maxwells...
Flux linkage...
Angle factor cos...

What it does

Magnetic flux counts how much magnetic field passes through a loop. For a flat coil in a uniform field the flux is the field strength times the coil area times the cosine of the angle between the field and the normal to the loop. Turning the coil edge on to the field brings the flux to zero.

This calculator returns the flux through one turn in webers, the same quantity in maxwells, and the flux linkage after multiplying by the number of turns. Flux linkage is the quantity whose rate of change sets the induced voltage in Faraday's law.

The default coil has 50 turns, each of area 0.02 m², in a field of 0.8 T with the field square to the coil. The flux per turn is 0.016 Wb, which is 1.6 million maxwells, and the total linkage is 0.8 Wb turns.

Area can be entered in square metres or square feet. The tool converts square feet to square metres with the exact factor 0.09290304 before calculating, so the weber result describes the same physical coil in either mode.

The calculation assumes a uniform field over the coil and a flat loop. Real coils have finite wire thickness and fields that vary across the winding, so the result is the idealised value used in introductory circuit and generator problems.

How to use

  1. Choose metric for square metres or imperial for square feet.
  2. Enter the magnetic field in teslas.
  3. Enter the area enclosed by one turn of the coil.
  4. Enter the angle between the field and the coil normal, from 0 to 90 degrees.
  5. Enter the whole number of turns and press calculate.
  6. Read the flux per turn first, then the linkage for the whole coil.

Formula

Φ = B × A × cos(θ), with flux linkage N × Φ.
B
Magnetic field strength in teslas.
A
Area of one turn in square metres, with square feet converted.
θ
Angle between the field and the normal to the coil, in degrees.
N
Number of turns in the coil, a whole number.

One weber is one tesla times one square metre, and it equals one hundred million maxwells, the cgs unit. The tool always works in square metres internally, so changing the unit system changes only the area entry and the flux label. Turns must be a whole number from 1 to 100,000, and the angle is limited to 0 to 90 degrees so the signed direction of flux does not need to be chosen.

Worked example

Example: 0.8 T across a 0.02 m² coil of 50 turns

Metric defaults with the field perpendicular to the coil face.

  1. Angle factor: cos(0°) = 1.000.
  2. Multiply field by area: 0.8 × 0.02 = 0.016 Wb per turn.
  3. Convert to maxwells: 0.016 × 100,000,000 = 1,600,000 Mx.
  4. Multiply by turns: 0.016 × 50 = 0.8 Wb turns of flux linkage.
  5. The tool shows 0.016 Wb, 1600000 Mx, 0.8 Wb-turns and 1.000.

Reference table

Flux as a coil is tilted in a 0.8 T field, area 0.02 m²
AnglecosFlux (Wb)
0°1.0000.016
30°0.8660.0139
45°0.7070.0113
60°0.5000.008
90°0.0000

Limits

  • Assumes the field is uniform across the whole coil area.
  • Uses a flat loop, so wound coils with depth are idealised.
  • Reports flux magnitude only, with no sign for field direction.
  • Does not compute induced voltage, which also needs the rate of change.

Common mistakes

  • Measuring the angle to the plane of the coil instead of to its normal.
  • Using the coil perimeter where the area is required.
  • Forgetting to multiply by turns when the question asks for linkage.
  • Mixing teslas with gauss without converting.
  • Entering square inches in the imperial mode, which expects square feet.

Try it yourself

Quick checks. Answers sit tucked under each question.

1.5 T, 0.1 m², 60°, one turn?

Flux 0.075 Wb, 7500000 Mx, linkage 0.075 Wb-turns, factor 0.500.

Imperial: 0.5 T across 0.21527821 ft², 100 turns?

Flux 0.01 Wb, 1000000 Mx, linkage 1 Wb-turns, angle factor 1.000.

Zero field across 1 m² with 10 turns?

Flux 0 Wb, 0 Mx, linkage 0 Wb-turns, angle factor 1.000.

Questions

What is magnetic flux?

A measure of how much magnetic field passes through a given area, measured in webers.

What is flux linkage?

Flux multiplied by the number of turns. Changing linkage over time induces a voltage.

How many maxwells in a weber?

One hundred million. The tool converts automatically.

Why does the coil angle matter?

Only the component of field perpendicular to the coil contributes, which is the cosine of the angle to the normal.

Can I enter square feet?

Yes. Choose imperial and the tool converts the area to square metres before calculating.

Does this calculate induced voltage?

No. It gives flux and linkage only. Voltage depends on how fast that linkage changes.

Sources

How this page was checked. The formula above was matched against the cited sources, and the worked example was run through the tool on this page before publishing. If you spot an error, contact us so we can fix it and note the correction.