Lapse Rate Calculator

Find how much an unsaturated air parcel cools as it rises, in metric or US weather units.

Physics and EnergyUpdated 2026-11-173 min read
Lapse Rate Calculator
Dry adiabatic rate
...
Temperature drop...
Temperature at the new height...

What it does

When a parcel of air rises, the pressure around it falls and the parcel expands. That expansion uses energy, so the parcel cools even though no heat leaves it. The rate for unsaturated air is called the dry adiabatic lapse rate and is close to 9.8 degrees Celsius per kilometre.

This calculator applies that rate to a height gain and a starting temperature. It works in metric units or in the Fahrenheit and feet convention used in US weather lessons, and it shows the rate, the temperature drop and the temperature at the new height.

With the defaults, the parcel starts at 20 °C and rises 1,000 m. The drop is 9.80 °C, leaving a temperature of 10.20 °C. Switching to imperial and entering 3,280.84 ft from 68 °F gives a 27.50 °F drop and 42.50 °F at the top.

The two published rates, 9.8 °C per km and 5.5 °F per 1,000 ft, are rounded in opposite directions and are not exactly equivalent after conversion. The tool uses each standard figure as given in its own unit system, so small differences appear when the same physical lift is entered both ways.

Real air does not always follow the dry rate. Once a parcel is saturated, water condenses and releases latent heat, reducing the rate. The surrounding air may also warm or cool with height at a different environmental lapse rate, which is what determines whether a lifted parcel keeps rising.

How to use

  1. Choose metric for metres and Celsius or imperial for feet and Fahrenheit.
  2. Enter how far the parcel rises from its starting height.
  3. Enter the temperature at the starting height.
  4. Press calculate and read the rate used for that system.
  5. Read the temperature drop, then the temperature at the new height.
  6. Check whether the parcel is saturated before applying a dry rate to real air.

Formula

Dry adiabatic rate = g / cp ≈ 9.8 °C per km, or 5.5 °F per 1,000 ft.
g
Acceleration due to gravity, about 9.81 m/s².
cp
Specific heat of dry air at constant pressure, about 1,005 J/(kg·K).
Height gain
How far the parcel rises, in metres or feet.
Starting temperature
Temperature before the lift, in °C or °F.

Dividing gravity by the specific heat of dry air gives about 9.76 K per kilometre, which weather references round to 9.8 °C per km. The same value converts to roughly 5.4 °F per 1,000 ft, while the commonly quoted US figure is 5.5 °F per 1,000 ft. The tool keeps both rounded standards so each mode matches the number taught in that system, and the slight mismatch between them is intentional.

Worked example

Example: a 1,000 m lift from 20 °C

Metric defaults, describing an unsaturated parcel.

  1. Convert the lift to kilometres: 1,000 m is 1 km.
  2. Apply the rate: 9.8 °C per km × 1 km = 9.80 °C drop.
  3. Subtract from the start: 20 minus 9.8 = 10.20 °C.
  4. Check the direction: the parcel cools, so the top temperature is lower than the start.
  5. The tool shows 9.8 °C per km, 9.80 °C and 10.20 °C.

Reference table

Dry cooling with height in metric units
Height gainedTemperature dropFrom 20 °C to
0 m0.00 °C20.00 °C
500 m4.90 °C15.10 °C
1,000 m9.80 °C10.20 °C
2,000 m19.60 °C0.40 °C
3,000 m29.40 °C-9.40 °C

Limits

  • Applies to unsaturated air only; saturated air cools at a lower rate.
  • Assumes the parcel does not exchange heat with its surroundings.
  • Uses a rounded constant rather than a value adjusted for humidity or pressure.
  • Does not predict cloud formation or whether the parcel will keep rising.

Common mistakes

  • Applying the dry rate to a parcel that is already saturated.
  • Mixing the 9.8 °C per km and 5.5 °F per 1,000 ft figures arithmetically as if they were identical.
  • Using height above sea level instead of height gained from the starting point.
  • Forgetting that the environment has its own lapse rate, which may differ.
  • Entering a negative height gain, which the tool rejects.

Try it yourself

Quick checks. Answers sit tucked under each question.

500 m lift from 15 °C?

Rate 9.8 °C per km, 4.90 °C drop, top temperature 10.10 °C.

Imperial: 5,000 ft lift from 70 °F?

Rate 5.5 °F per 1,000 ft, 27.50 °F drop, top temperature 42.50 °F.

No lift from 20 °C?

Rate 9.8 °C per km, 0.00 °C drop, top temperature stays 20.00 °C.

Questions

What is the dry adiabatic lapse rate?

The rate at which an unsaturated air parcel cools as it rises without exchanging heat, about 9.8 °C per kilometre.

Why does rising air cool?

Pressure falls with height, the parcel expands, and that expansion uses internal energy and lowers the temperature.

What is the moist rate?

A lower rate, because condensation releases latent heat. Its value depends on temperature and pressure.

Why does the imperial figure not match exactly?

The 5.5 °F per 1,000 ft figure is a rounded standard, not an exact conversion of 9.8 °C per km.

Is this the same as the environmental lapse rate?

No. The environmental rate is the actual temperature profile of the air around the parcel, measured with a radiosonde.

Do I need height above sea level?

No. Enter the height gained from the starting point, not the absolute altitude.

Sources

How this page was checked. The formula above was matched against the cited sources, and the worked example was run through the tool on this page before publishing. If you spot an error, contact us so we can fix it and note the correction.