Knudsen Number Calculator

Compare molecular mean free path with a length scale to classify a gas flow regime.

Physics and EnergyUpdated 2026-11-182 min read
Knudsen Number Calculator
About 68 nm for air at ordinary temperature and pressure.
Channel height, particle diameter or other geometric scale.
68 nm converted to inches.
1000 nm converted to inches.
Knudsen number
...
Flow regime...
Base 10 logarithm...

What it does

In a gas at ordinary scale, molecules collide with each other far more often than with the walls, so the fluid behaves as a continuous medium. In a very small channel or at low pressure, molecules travel a long way between collisions and the wall matters. The Knudsen number measures that shift.

It is simply the molecular mean free path divided by a characteristic length of the geometry. The right length depends on the application: a channel height for microfluidics, a particle diameter for aerosols, or an equivalent leak diameter for flow through a small opening.

Practitioners use broad bands to describe the result. Continuum flow sits below about 0.01, slip flow follows up to about 0.1, transition flow extends toward 10, and above that the molecules move largely independently. The boundaries are guides rather than sharp physical walls.

Because both inputs are lengths, any consistent unit works. This page offers nanometres and inches, echoes each value with its unit, and gives the same number in both systems when the inputs are converted.

How to use

  1. Pick Metric or Imperial to match your data source.
  2. Enter the molecular mean free path in the unit shown.
  3. Enter a characteristic length of the geometry in the same unit.
  4. Read the Knudsen number and the indicative regime label.
  5. Check the logarithm when values span many orders of magnitude.
  6. Switch systems with converted inputs to confirm the same answer.

Formula

Kn = mean free path / characteristic length, with both lengths in the same unit so the ratio has no dimension.
mean free path
Average distance a molecule travels between collisions, in nm or in.
characteristic length
Relevant geometric scale such as channel height or particle diameter, in the same unit.
Kn
Knudsen number, a dimensionless ratio.

The mean free path depends on pressure and temperature, so both inputs should describe the same gas state. At standard conditions air has a mean free path near 68 nm. The regime bands shown are conventional guides and can shift with geometry and surface properties.

Worked example

Example: air in a one micrometre channel

Metric mode with a mean free path of 68 nm and a characteristic length of 1000 nm.

  1. Both values are already in nanometres, so no conversion is needed.
  2. Divide 68 by 1000 to get 0.068.
  3. The tool prints Kn as 0.0680, with a base ten logarithm of -1.17.
  4. That value falls in the slip flow band, below 0.1 but above 0.01.
  5. Imperial check: 68 nm is 0.0000026771653543307086 in.
  6. The length of 1000 nm is 0.00003937007874015748 in.
  7. Their quotient is still 0.0680, so the regime stays slip flow.

Reference table

Knudsen number as the length changes, with a 68 nm mean free path
Characteristic length (nm)Knudsen numberRegime
1000.6800transition
10000.0680slip flow
100000.0068continuum

Limits

  • The characteristic length convention depends on the application.
  • Regime boundaries are approximate guides.
  • Mean free path changes with pressure and temperature.
  • Does not itself compute a flow rate or heat transfer coefficient.

Common mistakes

  • Using nanometres for one input and inches for the other.
  • Mixing a radius with a diameter between different sources.
  • Using a mean free path measured at a different pressure.
  • Treating the regime label as an exact physical boundary.
  • Forgetting that very small channels can be in continuum flow if pressure is high.

Try it yourself

Quick checks. Answers sit tucked under each question.

Mean free path 68 nm and length 100 nm. What is Kn?

0.6800, which the tool labels transition flow.

What does Imperial mode show for the worked example?

0.0680 and slip flow, using 0.0000026771653543307086 in and 0.00003937007874015748 in.

If the length shrinks by a factor of ten, what happens to Kn?

It grows tenfold from 0.0680 to 0.6800, moving from slip flow to transition flow.

Questions

What is the mean free path?

The average distance a molecule travels before colliding with another molecule.

Why does the length choice matter?

Different geometries set different scales. A channel height and a particle diameter give different Kn for the same gas.

What is continuum flow?

Molecule to molecule collisions dominate, so the gas can be treated as a continuous fluid.

What is free molecular flow?

Molecules mostly interact with walls rather than each other, which happens at very high Kn.

Do I need both unit systems?

No. Use the one matching your source data. Converted inputs give the same dimensionless result.

Does pressure matter?

Yes. Raising pressure shortens the mean free path and lowers Kn.

Sources

How this page was checked. The formula above was matched against the cited sources, and the worked example was run through the tool on this page before publishing. If you spot an error, contact us so we can fix it and note the correction.