Freundlich Adsorption Calculator

Estimate adsorbed amount from the Freundlich empirical isotherm and equilibrium concentration.

Chemistry and LabUpdated 2026-11-202 min read
Freundlich Adsorption Calculator
Adsorbed amount
...
Log form value...
Power 1/n...

What it does

The Freundlich isotherm is an empirical relationship between the amount of a substance adsorbed onto a solid and its concentration in the surrounding fluid at equilibrium. It is widely used for activated carbon, soils and other heterogeneous adsorbents because it is simple and fits many real datasets over a limited range.

The equation is a power law. The adsorbed amount per unit mass equals K times concentration raised to the power one over n. Taking logarithms turns it into a straight line, with slope one over n and intercept log K. That log form is how the constants are usually found from measurements.

The exponent carries physical meaning. When one over n is less than one, adsorption becomes less efficient as concentration rises, which is typical of heterogeneous surfaces with a range of site energies. A value near one suggests nearly linear partitioning.

The Freundlich model does not include a maximum capacity. At very high concentration it predicts uptake that grows without limit, which is not physically realistic. It should only be used within the range where the constants were fitted, and it should not be compared directly with a Langmuir capacity parameter.

This tool evaluates the power law and its log form for one concentration. It uses the convention with K outside the power and exponent one over n, which is common in engineering courses. Some references place the constant inside the power, so check the convention before copying constants from a source.

How to use

  1. Obtain K and n from a Freundlich plot of your own adsorption data.
  2. Check which convention your source uses for the constant.
  3. Enter K, n and the equilibrium concentration in matching units.
  4. Read the predicted adsorbed amount.
  5. Read the exponent one over n and the log form value.
  6. Confirm the concentration is inside the range used to fit the constants.

Formula

q = K x C^(1/n), and log10(q) = log10(K) + (1/n) x log10(C).
q
Adsorbed amount per unit mass of adsorbent.
K
Freundlich constant with units that depend on n and C.
n
Dimensionless empirical exponent.
C
Equilibrium concentration in the fluid.
1/n
Slope of the log uptake versus log concentration line.

The units of K depend on the exponent, so never transfer K between systems that use different concentration units. At zero concentration the power law gives zero uptake but the logarithm is undefined, so the tool reports the log form as undefined at that point.

Worked example

Example: K = 2, n = 2 and C = 4

Defaults: Freundlich constant 2, exponent 2 and equilibrium concentration 4.

  1. Find the exponent: 1 / n = 1 / 2 = 0.5.
  2. Raise concentration to that power: 4^0.5 = 2.
  3. Multiply by K: 2 x 2 = 4.000.
  4. Check the log form: log10(2) + 0.5 x log10(4) = 0.301 + 0.301 = 0.602.
  5. The tool shows 4.000, 0.602 and 0.500.

Reference table

Uptake at several concentrations for K = 2 and n = 2
ConcentrationUptakeLog10 uptake
12.0000.301
44.0000.602
96.0000.778
168.0000.903

Limits

  • Empirical, with no theoretical saturation capacity.
  • Valid only over the concentration range used to fit K and n.
  • Constant conventions differ between sources.
  • Does not describe multilayer adsorption or strong surface heterogeneity changes.

Common mistakes

  • Copying K from a source that uses a different convention.
  • Extrapolating far beyond the fitted concentration range.
  • Treating 1/n as the exponent when the source writes n in that position.
  • Expecting the model to level off like a Langmuir isotherm.
  • Mixing concentration units between K and the input.

Try it yourself

Quick checks. Answers sit tucked under each question.

At zero concentration, what does the tool show?

The adsorbed amount is 0.000, but the log form is reported as Undefined at zero because the logarithm of zero does not exist.

What does the exponent 0.500 mean?

It is the slope of log uptake against log concentration. Uptake grows as the square root of concentration for this example.

Why is there no maximum uptake in the output?

The Freundlich equation is a power law with no saturation term, so it predicts uptake growing indefinitely. That is why it must be used within a fitted range.

Questions

What is the Freundlich isotherm?

An empirical power law relating adsorbed amount to equilibrium concentration at fixed temperature.

How are K and n found?

By plotting log uptake against log concentration and reading the intercept and slope.

How is it different from Langmuir?

Langmuir has a finite monolayer capacity and a theoretical basis. Freundlich is empirical and has no saturation limit.

What does 1/n tell me?

It describes how adsorption efficiency changes with concentration, often less than one for heterogeneous surfaces.

Can I compare K values between studies?

Only when concentration and uptake units and the constant convention match.

Where is it used?

In activated carbon design, soil chemistry, water treatment and catalyst characterization.

Sources

How this page was checked. The formula above was matched against the cited sources, and the worked example was run through the tool on this page before publishing. If you spot an error, contact us so we can fix it and note the correction.