Current Density Calculator
Find the current flowing through each unit area of a conductor.
What it does
Current density measures how much electric current passes through each unit of cross-sectional area. It is a vector quantity whose magnitude is the current divided by the area perpendicular to the flow, and it is central to understanding heating and material limits in conductors.
This calculator divides the current by the area you enter and reports the answer in amperes per square metre and amperes per square millimetre. Area must be entered in square millimetres.
The default case carries 10 amperes through a cross section of 2.5 square millimetres. The density is four amps per square millimetre, or four million amps per square metre.
Current density is what determines the heating effect in a wire, not the total current alone. A small wire carrying a given current runs hotter than a large one because the same charge must pass through less material.
The calculation assumes the current is spread evenly across the cross section. At high frequencies the skin effect concentrates current near the surface, so the average value no longer tells the full story.
How to use
- Enter the current flowing through the conductor.
- Enter its cross-sectional area in square millimetres.
- Press calculate and read the current density.
- Use the per square millimetre figure for quick comparisons.
- Remember that heating depends on density, not just total current.
- Keep the sign if you are tracking direction.
Formula
- I
- Current through the conductor in amperes.
- A
- Cross-sectional area in square metres after conversion.
- J
- Current density in amperes per square metre.
One square millimetre is ten to the minus six square metres. Area must be above zero. A negative current is accepted and produces a negative density, which indicates flow in the opposite direction.
Worked example
Example: 10 A through 2.5 mm²
The form opens with these defaults so the result is already shown.
- Note the current of 10 A and area of 2.5 mm².
- Convert area: 2.5 mm² is 2.5e-6 m².
- Divide 10 by 2.5e-6 to get 4e6 A/m².
- Dividing 10 by 2.5 directly gives 4.0000 A/mm².
- The tool shows 4e6 A/m² and 4.0000 A/mm².
Reference table
| Current | Density (A/m²) | Density (A/mm²) |
|---|---|---|
| -5 A | -2e6 A/m² | -2.0000 |
| 5 A | 2e6 A/m² | 2.0000 |
| 10 A | 4e6 A/m² | 4.0000 |
| 20 A | 8e6 A/m² | 8.0000 |
Limits
- Assumes uniform current across the section.
- Ignores the skin effect at high frequency.
- Does not calculate the resulting temperature rise.
- Uses a single area even if the conductor tapers.
Common mistakes
- Using diameter where area is required.
- Entering area in square centimetres.
- Confusing current density with total current.
- Ignoring heating in a small conductor.
- Forgetting that alternating current may not fill the section.
Try it yourself
Quick checks. Answers sit tucked under each question.
20 A through 5 mm²?
4e6 A/m², or 4.0000 A/mm².
Negative 5 A through 2.5 mm²?
-2e6 A/m², or -2.0000 A/mm².
Questions
What is current density?
Current per unit cross-sectional area, usually in amperes per square metre.
What is the formula?
Current divided by the area perpendicular to the flow.
Why does it matter?
It determines heating and whether a conductor is within its safe rating.
Can it be negative?
Yes. A negative value indicates flow in the opposite direction.
What area unit is expected?
Square millimetres, which the tool converts before calculating.
Does current fill the whole wire?
For direct current yes. At high frequencies it concentrates near the surface.