Curie-to-Becquerel Converter

Convert curies to becquerels, gigabecquerels, and terabecquerels for activity units.

Unit ConvertersUpdated 2026-11-182 min read
Curie-to-Becquerel Converter
Converted activity
...
Activity in becquerels...
Activity in gigabecquerels...

What it does

Activity measures how many atomic nuclei decay each second. The becquerel is the SI unit and equals one decay per second. The curie is an older unit based on the activity of radium and is still common in some medical and industrial settings.

NIST lists one curie as 3.7 times ten to the tenth becquerels in its conversion tables. That factor is used directly here, along with the SI prefixes giga and tera for larger values.

Enter an activity in curies or one of the metric units and choose a target. The result is shown with becquerels and gigabecquerels, which are the forms most often printed on source certificates.

Activity is not dose. How much radiation a person receives depends on the type of emission, the energy, and how the source is handled. This converter changes activity units only.

How to use

  1. Enter the activity in curies or another listed unit.
  2. Choose the matching source unit.
  3. Choose becquerels, gigabecquerels, or terabecquerels as the target.
  4. Read the converted activity in the main box.
  5. Check the becquerel and gigabecquerel rows.
  6. Switch the menus to convert an SI activity back to curies.

Formula

becquerels = value x factor(from). result = becquerels / factor(to), with 1 Ci = 3.7e10 Bq.
Ci
Curie, an activity of 3.7 times ten to the tenth decays per second.
Bq
Becquerel, one decay per second.
factor(from)
Becquerels in one of the starting unit.

NIST lists the curie at 3.7E+10 becquerels in Appendix B.8. The gigabecquerel and terabecquerel follow from the SI prefixes giga and tera. The tool changes activity units and does not convert to absorbed dose or dose equivalent.

Worked example

Example: one curie to becquerels

A one curie source, expressed in becquerels and gigabecquerels.

  1. NIST factor: one curie is 3.7e10 becquerels.
  2. Multiply: 1 x 3.7e10 = 3.7e10 Bq.
  3. Tool shows 3.7e10 Bq.
  4. Gigabecquerel check: 3.7e10 / 1e9 = 37 GBq.
  5. Terabecquerel check: 3.7e10 / 1e12 = 0.037 TBq.
  6. Reverse check: 37 GBq x 1e9 / 3.7e10 = 1 curie.

Reference table

NIST activity factors
UnitBecquerels per unitCuries per unitTypical use
Curie3.7e101Legacy sources
Becquerel12.7027e-11SI activity
Gigabecquerel1e90.027027Medical sources
Terabecquerel1e1227.027Large sources

Limits

  • Converts activity only, not absorbed dose or dose equivalent.
  • Does not model decay over time or half life.
  • Writes large results in scientific notation.
  • Uses the exact NIST curie factor rather than a rounded value.

Common mistakes

  • Treating becquerels as a measure of radiation dose.
  • Mixing curies with rads or rems.
  • Dropping the exponent when reading a becquerel result.
  • Ignoring decay when comparing sources measured on different dates.

Try it yourself

Quick checks. Answers sit tucked under each question.

Convert 0.1 curie to becquerels.

0.1 x 3.7e10 = 3.7e9 Bq.

How many gigabecquerels in 5 curies?

5 x 37 = 185 GBq.

Convert 37 GBq back to curies.

37e9 / 3.7e10 = 1 curie.

Questions

How many becquerels in a curie?

3.7 times ten to the tenth, or 37 gigabecquerels.

Is a becquerel a dose unit?

No. It measures activity, the number of decays per second.

Why is the curie still used?

Many older regulations and labels use it, so conversions remain useful.

Can I convert becquerels back to curies?

Yes. Choose becquerels as the source and curies as the target.

How many terabecquerels are in a curie?

0.037 TBq.

Does this account for half life?

No. Activity at a given date is assumed; use a half life calculator for decay over time.

Sources

How this page was checked. The formula above was matched against the cited sources, and the worked example was run through the tool on this page before publishing. If you spot an error, contact us so we can fix it and note the correction.