Cavitation Calculator
Compute the cavitation number from static pressure, vapour pressure, density and speed.
What it does
Cavitation happens when the local pressure in a liquid falls to its vapour pressure and small vapour bubbles form. When those bubbles collapse downstream they can erode surfaces, create noise and reduce pump performance. The cavitation number is the dimensionless group used to compare operating conditions with the onset of cavitation.
It is defined as the difference between static pressure and vapour pressure divided by the dynamic pressure of the flow. A large margin above vapour pressure or a low flow speed gives a large cavitation number and a safer condition. A small number means cavitation is more likely.
Pressure must be absolute. Using gauge pressure would understate the margin and give the wrong answer. Vapour pressure should be taken at the liquid temperature, since it rises rapidly as the liquid warms.
For the default values, water at room temperature with 200 kPa absolute pressure and a speed of 10 metres per second gives a cavitation number near 3.95. The dynamic pressure is 50 kPa and the margin above vapour pressure is about 197.7 kPa.
The cavitation number is not a universal pass or fail threshold. Inception depends on geometry, surface condition, dissolved gas nuclei, turbulence and the time available for bubbles to grow. Engineers compare it with an application specific inception value measured or estimated for the equipment.
How to use
- Enter the absolute static pressure at the reference point.
- Enter the vapour pressure of the liquid at its temperature.
- Enter the liquid density.
- Enter the corresponding reference flow speed.
- Read the cavitation number, dynamic pressure and pressure margin.
- Compare the number with an inception value for your equipment.
Formula
- p
- Absolute static pressure at the reference point.
- p_v
- Saturated vapour pressure of the liquid.
- rho
- Liquid density in kg per cubic metre.
- v
- Reference flow speed in metres per second.
- sigma
- Dimensionless cavitation number.
The tool converts pressures from kilopascals to pascals before dividing by dynamic pressure. Use local static pressure and local speed for a local cavitation number, or upstream values for the conventional system level number. Do not substitute stagnation pressure unless the chosen definition calls for it.
Worked example
Example: water at 200 kPa and 10 m/s
Defaults: pressure 200 kPa absolute, vapour pressure 2.3 kPa, density 1000 kg/m³ and speed 10 m/s.
- Pressure margin: 200 - 2.3 = 197.7 kPa.
- Dynamic pressure: 0.5 x 1000 x 10² = 50,000 Pa, or 50.00 kPa.
- Convert margin to pascals: 197,700 Pa.
- Divide: 197,700 / 50,000 = 3.954.
- The tool shows 3.954, 50.00 kPa and 197.70 kPa.
Reference table
| Speed | Dynamic pressure | Cavitation number |
|---|---|---|
| 5 m/s | 12.50 kPa | 15.82 |
| 10 m/s | 50.00 kPa | 3.95 |
| 20 m/s | 200.00 kPa | 0.989 |
| 30 m/s | 450.00 kPa | 0.44 |
Limits
- Does not predict cavitation inception on its own.
- Requires consistent static pressure and speed reference points.
- Vapour pressure changes with temperature.
- Ignores dissolved gas and surface condition effects.
Common mistakes
- Using gauge pressure instead of absolute pressure.
- Forgetting to convert kilopascals to pascals.
- Using a vapour pressure for the wrong temperature.
- Treating the number as a universal threshold.
- Mixing local and upstream reference conditions.
Try it yourself
Quick checks. Answers sit tucked under each question.
What happens at 20 m/s with the other defaults?
Dynamic pressure rises to 200.00 kPa and the cavitation number falls to 0.989, so cavitation is much more likely.
Why must pressure be absolute?
The vapour pressure is an absolute pressure, so subtracting a gauge reading would give an incorrect margin.
What if vapour pressure exceeds static pressure?
The tool returns an error because the liquid would already be boiling and the cavitation number would be negative.
Questions
What is cavitation?
The formation and collapse of vapour bubbles when local pressure falls to vapour pressure.
Why is it damaging?
Collapsing bubbles produce local shock waves that erode metal and create noise and vibration.
What is a typical cavitation number?
It depends on the application. Larger values are safer, and the inception value is equipment specific.
Does temperature matter?
Yes. Warmer liquid has higher vapour pressure, which reduces the margin to cavitation.
Can I use gauge pressure?
No. The definition uses absolute pressure.
Where is this used?
In pump design, propellers, turbines, valves and any high speed liquid flow.
Sources
- California Institute of Technology, Cavitation Parameters
- MIT OpenCourseWare, Marine Hydrodynamics Lecture 6
- PNNL hosted paper: Cavitation number definition