Capacitance Calculator
Find the capacitance of parallel plates from area, separation, and dielectric in metric or imperial units.
What it does
A parallel plate capacitor stores charge on two flat conductors separated by a small gap. Its capacitance depends only on geometry and the material between the plates. Doubling the plate area doubles the capacitance, while doubling the gap halves it.
This tool offers metric and imperial inputs. Metric mode takes area in square meters and separation in millimeters. Imperial mode takes area in square inches and separation in inches. Both convert to meters internally, so the capacitance result is identical for equivalent dimensions.
The calculation uses C equals k times epsilon nought times A divided by d. The constant epsilon nought is the permittivity of free space, listed by the National Institute of Standards and Technology as about 8.8541878188 times ten to the power of minus 12 farads per meter. The symbol k is the relative permittivity of the dielectric.
The default case uses plates of 0.01 square meters, a gap of 1 millimeter, and air with k equal to 1. That gives about 88.54 picofarads. The tool shows the result in the most readable subunit and also reports the value in picofarads for easy comparison.
Real capacitors have fringing fields at the plate edges and leads that add stray capacitance. The formula here assumes large plates with a small, uniform gap, so it is a good estimate for a parallel plate geometry rather than a model of every physical part.
How to use
- Choose Metric or Imperial for the plate dimensions.
- Enter the area of one plate in the units shown.
- Enter the gap between the plates.
- Enter the relative permittivity, using 1 for air.
- Read the main capacitance result and the picofarad value beside it.
- Check the dimensions used row to confirm the tool parsed your inputs.
Formula
- A
- Area of one plate. Metric inputs are square meters, imperial inputs are square inches.
- d
- Separation between plates, converted internally to meters.
- k
- Relative permittivity of the dielectric, dimensionless. Air is about 1.
- epsilon0
- Permittivity of free space, about 8.8541878188 times ten to the power of minus 12 farads per meter.
Imperial inputs are converted with 1 inch equal to 0.0254 meter and 1 square inch equal to 0.00064516 square meter. Since the farad is an SI unit, both systems produce the same capacitance for the same physical plates. A larger dielectric constant increases capacitance because the material polarizes and allows more charge at the same voltage.
Worked example
Example: air filled plates with a 1 mm gap
The page opens in Metric mode with area 0.01 m2, separation 1 mm, and k = 1.
- Convert the gap to meters: 1 mm is 0.001 m.
- Effective permittivity is k times epsilon0, which is 1 times 8.8541878188 times ten to the power of minus 12 F/m.
- Multiply by area: 8.8541878188 times ten to the power of minus 12 times 0.01 gives 8.8541878188 times ten to the power of minus 14.
- Divide by the gap of 0.001 m to get 8.8541878188 times ten to the power of minus 11 F.
- Convert to picofarads by multiplying by ten to the power of 12, giving 88.541878188 pF.
- The tool reports 88.54 pF with dimensions 0.0100 m2 and 1.0000 mm.
- Imperial mode with 15.5 in2 and 0.03937 in returns the same 88.54 pF.
Reference table
| Plate area | Separation | Relative permittivity | Capacitance |
|---|---|---|---|
| 0.01 m2 | 1 mm | 1 | 88.54 pF |
| 0.02 m2 | 2 mm | 1 | 88.54 pF |
| 0.01 m2 | 2 mm | 1 | 44.27 pF |
| 0.01 m2 | 1 mm | 2 | 177.08 pF |
Limits
- Assumes flat, parallel plates with a uniform gap and no edge fringing.
- Relative permittivity must be above zero and at most 10,000.
- Does not model breakdown voltage or leakage through the dielectric.
- Displays capacitance to two or more decimal places while keeping full precision internally.
Common mistakes
- Using plate perimeter instead of plate area.
- Entering the gap in millimeters while the tool expects meters, or vice versa.
- Forgetting to include the dielectric constant when one is present.
- Treating an imperial area as if it were square meters.
- Confusing capacitance in farads with charge in coulombs.
Try it yourself
Quick checks. Answers sit tucked under each question.
Plates of 0.02 m2 separated by 2 mm in air. Capacitance?
88.54 pF. The area to gap ratio matches the worked example.
Same 0.01 m2 plates at 1 mm with k = 2. Capacitance?
177.08 pF. Doubling the dielectric constant doubles capacitance.
Imperial: 15.5 in2 at 0.03937 in in air. Capacitance?
88.54 pF, the same as 0.01 m2 at 1 mm because the physical dimensions match.
Questions
What is a farad?
It is the SI unit of capacitance, equal to one coulomb of charge per volt of potential difference.
Why does a dielectric increase capacitance?
The material polarizes in the field, which lets the plates hold more charge at the same voltage.
Can I mix metric and imperial inputs?
No. Choose one system, and the tool converts that system's inputs to meters before calculating.
What relative permittivity should I use for air?
Use 1. Air is close enough to vacuum for most estimates.
Does the plate thickness matter?
No. Only the facing area, the gap, and the dielectric enter the parallel plate formula.
Why does doubling the gap halve the capacitance?
A wider gap weakens the field for a given charge, so less charge is stored per volt.
Sources
- HyperPhysics, Georgia State University: parallel plate capacitor
- NIST, CODATA value of the vacuum electric permittivity
- NIST Guide to the SI, Appendix B.8: inch and foot conversion factors